Advanced Static VAR Generator
What is ASVG?
ASVG stands for Advanced Static Var Generator.
ASVG acts as a current source that generates a compensation current working as a dynamic current source. It monitors the current phase angle and generates real time compensation current to achieve the set displacement power factor.
Advanced static var generator, additionally monitors harmonics up to order of 15th Level and compensates the same on real time basis, thus improving the power quality.
A correctly sized ASVG can not only correct displacement Power factor, but also it can reduce harmonics to <5% THDi.
Dealing in both can result in true unity power factor.
ASVG acts as a current source that generates a compensation current working as a dynamic current source. It monitors the current phase angle and generates real time compensation current to achieve the set displacement power factor.
Advanced static var generator, additionally monitors harmonics up to order of 15th Level and compensates the same on real time basis, thus improving the power quality.
A correctly sized ASVG can not only correct displacement Power factor, but also it can reduce harmonics to <5% THDi.
Dealing in both can result in true unity power factor.
Working Principle of ASVG
When the load generates inductive or capacitive current, it makes load current lagging or leading the voltage.
ASVG detects the phase angle difference and generates leading or lagging current into the grid, making the phase angle of current almost the same as that of voltage on the transformer side, which corrects the fundamental power factor to almost unity.
ASVG draws the harmonic current from the supply grid in such a way that the magnitude of its current is same as that of the load side harmonic current, whereas its phase is opposite with respect to that of the load side harmonic current, which ensures that the effective value of the harmonic current on the supply side reduces to a negligible level.
ASVG detects the phase angle difference and generates leading or lagging current into the grid, making the phase angle of current almost the same as that of voltage on the transformer side, which corrects the fundamental power factor to almost unity.
ASVG draws the harmonic current from the supply grid in such a way that the magnitude of its current is same as that of the load side harmonic current, whereas its phase is opposite with respect to that of the load side harmonic current, which ensures that the effective value of the harmonic current on the supply side reduces to a negligible level.
Compensation of reactive power and harmonics with Selec ASVG
ompensation of series load balancing for 3P3W and 3P4W
ASVG can correct unbalance between phase – phase and phase to neutral
Therefore, ASVG is a perfect solution to reactive power compensation with unbalanced load
ASVG detect the current of each phase, Even if the current is different in each phase, it individually feeds compensation current to each phase to improve the power factor.
Therefore, ASVG is a perfect solution to reactive power compensation with unbalanced load
ASVG detect the current of each phase, Even if the current is different in each phase, it individually feeds compensation current to each phase to improve the power factor.
Advantages of using ASVG
Works under unbalance grid condition
Output current is not affected by the mains voltage fluctuation, providing stable support for mains voltage.
Modular design, easy extension
It is easy to expand the system as 8 modules can be connected in parallel. ASVG can also be used as a hybrid solution in combination with conventional capacitor based system.
Highly reliable and safe
Robust design for power system eliminates resonance problems, with no more amplified harmonic current and voltage. It extends components life cycle and protects the system.
Control and monitoring through ASVG
User can monitor and control the system parameters via Ethernet or serial communication.
Data logging and alarm can also be done User can monitor & control HMI screen using VNC software on PC or laptop.
Data can be monitored using selec IoT platform and can be accessed across the world.
Data logging and alarm can also be done User can monitor & control HMI screen using VNC software on PC or laptop.
Data can be monitored using selec IoT platform and can be accessed across the world.
Features of ASVG
Controllable reactive current source
Compensates current harmonics up to 15th order
Stepless & precise control
Compensates current unbalance created by the load
Leading and lagging reactive power mitigation
Individual correction of current on all three phases
Instant response time of 50 micro sec & full response less than 1 cycle
Modular arrangement – Parallel operation up to 8 modules
Can be installed along with conventional APFC panel
Compensates current harmonics up to 15th order
Stepless & precise control
Compensates current unbalance created by the load
Leading and lagging reactive power mitigation
Individual correction of current on all three phases
Instant response time of 50 micro sec & full response less than 1 cycle
Modular arrangement – Parallel operation up to 8 modules
Can be installed along with conventional APFC panel
Advantage of using ASVG over conventional Power factor correction system
TECHNICAL SPECIFICATION
Advanced Static VAr Generator
Instantaneous and stepless compensation for dynamic reactive power & unbalanced load, mitigate Harmonics upto 15th order.
Advanced Static Var Generator, 50 kVAr, 3P4W, Rack or Wall mounted
Advanced Static Var Generator, 100 kVAr, 3P4W, Rack or Wall mounted
Rated voltage | 308V to 480V±15% |
Frequency | 50/60 Hz (±2.5 Hz) |
Overall efficiency | > 97% |
Power grid structure | 3P3W / 3P4W |
CT ratio | Selectable through HMI up to 10000/5A |
CT location | Grid side / Load side |
Parallel operation | 8 |
Response time | 50 μsec and full response less than 1 cycle |
Target power factor | Adjustable from -1 to +1 |
Normal spectrum of compensation | Upto 15th harmonics |
Protection | Over current, over voltage, over temperature, IGBT saturation protection, grid fault |
Product Code | Description |
---|---|
ASVG-050-RCK-4P-04 | Advanced Static Var Generator- 50kVAr- Rack Type- 3P4W- 4.3" HMI |
ASVG-050-WLL-4P-04 | Advanced Static Var Generator- 50kVAr- Wall Mount- 3P4W- 4.3" HMI |
ASVG-050-WLL-4P-XX | Advanced Static Var Generator- 50kVAr- Wall Mount- 3P4W- Without Display |
ORDERING INFORMATION
Eg : ASVG-050-WLL-4P-04